The UUKL smoke control system is designed to protect building occupants and ensure their safety in the event of a fire.
This system complies with the UL 864 UUKL standard and is capable of operating HVAC systems during emergencies to maintain safe evacuation routes and contain smoke within the fire zone.
It includes Firefighters Smoke Control Stations (FSCS), providing complete control and real-time management of smoke conditions.
The system is designed to easily integrate with other building automation systems, ensuring a unified and advanced solution for emergency management.
Why Choose Optimum?
Optimum specializes in providing customized solutions for UUKL smoke control systems, with a focus on safety, sustainability, and technological innovation.
We offer comprehensive services, including consulting, design, installation, and ongoing maintenance, along with full support from our expert team throughout the entire process.
Through smart and efficient solutions, we aim to enhance the safety and management of your buildings, giving you peace of mind at all times.
Contact us today to discover how Optimum can safeguard your building with the most advanced technology available!
IRON CONTROL PANEL
The IRON Fire Control Panel is a conventional fire detection and alarm system designed to manage emergency situations in buildings. The system connects to smoke detectors, heat detectors, and manual alarm call points, supporting the management of 2–4 zones with up to 32 detectors and call points per zone.Upon detecting fire or smoke, the panel activates audible and visual alarms, including alarm bells, and provides outputs for faults and events. It features a test mode for easy maintenance, customizable detection thresholds, and comes in a high-quality metal enclosure. The system complies with EN 54-2 and EN 54-4 standardsMore Info
CLVR CONTROL PANEL
A fire control panel designed to detect and prevent fires across up to 12 distinct detection zones. The panel identifies and alerts through connections to detectors and alarm call points, activates alarm bells and notifications, and supports external activation of extinguishing systems. It features a test mode for easy maintenance and complies with EN 54-2 and EN 54-4 standardsMore Info
LONDON Control Panel
A fire detection panel designed to manage up to 128 zones through separate modules, with support for connecting detectors and alarm call points for each zone. The panel detects and alerts for fire or smoke events, activates alarm bells, and provides outputs for controlling emergency and fire suppression systems. It features customizable programming, a test mode for easy maintenance, and complies with EN 54-2 and EN 54-4 standardsMore Info
Convetional Heat Sensor C50H
A heat detector that identifies rapid temperature increases and triggers an alarm at a fixed temperature of 60°C, particularly effective for slow-developing fires. It features a low-profile design (total height less than 42 mm), easy polarity-free installation, and a red LED indicator for alarm status. Made from heat-resistant ABS, it is compatible with the C50 detector family and certified to EN 54-5 Class A2 standards with CE markingMore Info
Conventional Heat Sensor C50T/C50TB
A heat detector designed to detect temperature increases in various environments. The C50T model triggers an alarm at a static temperature of 60°C, while the C50TB model is designed for hotter environments and activates at 70°C. It features a low-profile design, easy polarity-free installation, and a red LED indicator for alarm status. Certified to EN 54-5 standards with CE markingMore Info
גלאי עשן וחום קונבנציונלי C50SH
גלאי המשלב חיישני עשן וחום לזיהוי מוקדם של שריפות. החיישן האופטי מזהה חלקיקי עשן, בעוד החיישן התרמי מגיב לעלייה מהירה בטמפרטורה, ומפעיל אזעקה בטמפרטורה קבועה של 60°C. בעל פרופיל נמוך, התקנה קלה ללא תלות בקוטביות, ונורית LED אדומה המציינת מצב אזעקה. מאושר בתקן EN 54-5 Class A2R ו-EN 54-7 עם סימון CE.